Product Introduction
ACD-3151 Double-Flange Differential-Pressure Liquid Level Transmitter is a new liquid level meter based on years of experience in advanced technology, independent research and development. It applies the most advanced ANCN micro power consumption technology and software compensation technology. Its key components and parts are all imported from E+H OEM brand. The instrument was assembled strictly with testing , aging , to ensure the quality of instrument.



- Suitable to the medium With solid particles, suspended solids, precipitation, easy to crystallization, high temperature and other special viscous;
- For the level measure of various of sealed oil tank, water tank, and liquid tank or processing tank;
- Need to isolate Transmitter from the high temperature medium;
- Suitable to be used for places where it request isolation the transmitter from the high temperature medium which would be changed or crystallized due to environment or temperature change;
- the measurement process must be kept sanitary, and the corrosive or viscous liquid is strictly prohibited;

- High Accuracy ;
- High Stability ;
- Small size, light weight , strong vibration resistance;
- Adjustable damping;
-High performance of one way overload protection;
- No movable components, less maintenance;
- Unified structure for whole series instruments, strong interchangeable parts;
- The diaphragm material to contact the media, can be selected;
- Explosion proof structure, All-weather use;

Measure Range
Differential Pressure:0~1kPa 0~4MPa
Accuracy Grade
0.075%F.S 、 0.1%F.S 、 0.2%F.S
Stability
Superior to 0.2%FS/Year
Output Signal
(4~20)mA(24V DC,two wire)
Communication
HART 、 RS485
Power Supply
(10~30)V DC( for communication )
Acquisition Speed
(0.1~10)S/A (S=second, A=acquisition ),default is 0.2S/A, time is settable
Environmental Temperature
(-30~70)℃
Relative Humidity
<90%
Atmospheric Pressure
(86~106)kPa
Others
Correction reference environment temperature: :20℃±2℃
When 0.075%F.S , the gauge environment temperature :(0~50)℃
The Medium temperature
Normal:(-40~85)℃
Wide Temperature:(-70~400)℃ Flange type installation, filled with high temperature silicone oil
Display
5 digits LCD backlight display + percentage bar chart
Protection Grade
IP65
Explosion Proof Grade
ExdIIBT6 Gb
Overload Pressure
Max. Hydrostatic Pressure:16MPa
One way Max. Overload Pressure:16MPa
Two way Max. Overload Pressure:24MPa
Note :Overload pressure depends on the measure range
Software
AncnView-T analysis software ( with USB communication), can Export instrument data, automatic storage, automatic drawing temperature curve, can be exported to Excel form, read, print,save.