Product Introduction
ACD-2KL is a automatic control instrument with sight display, alarm and control functions. Using relay contact output alarm, you can set the upper and lower limit alarm and back difference , then drives a relay output. Signal isolation design, eliminate interference. Its advantages of high control precision, fast response, stable operation, small size, convenient installation , makes it an ideal substitute for electrical contact instrument.


Utility model patent certificate
①ZL200820028605.1 《Buttons and LCD display of digital instrument》
②ZL200920062360.9 《Constant current driving circuit with micro power consumption low voltage drop sensor》
Appearance design patent certificate
①ZL200830019531.0 《Instrument (Pressure Testing Gauge)》

- For the level measure of well, pond, water tower, etc;
- For the level measure and monitoring of water conservancy and hydropower;
- Water level measurement of urban water supply and sewage treatment;
- Liquid level measurement and control in industrial field;
- Liquid level measuring for all kinds of open tank, water tank and liquid tank;

- Support liquid density modification, can be directly measured in different media;
- Acquisition speed (0.1~10)S/A, settable freely;
- RS485 communication , (4~20)mA、(1~5)V output are available for choice;
- Upper , lower limit relay, output independently;
- Buttons pressed with magnetic induction pen, exempt from interference, not easy to damage;
- Visual Level percentage bar chart display, easy to understand;
- Signal isolation technology, anti electromagnetic, frequency interference technology, to ensure that the data is correct;
- Zero Self-Stability technology, with temperature compensation automatically, stability reliable;

Measure Range
0~1mH2O~200mH2O ( any scope within it )
Accuracy
0.05%F.S 、 0.1%F.S 、 0.2%F.S 、 0.5%F.S
Output Signal
(4~20)mA(24V DC,three wire)
Communication
RS485
Range Migration
Suggested not over load than 3:1 ( to the electrical current output signals )
Relay node capacity
240VAC/1A、30VDC/2A
Power Supply
External:(10~30)V DC
Acquisition Speed
(0.1~10)S/A,default is 0.25S/A,(S=second, A=acquisition) , time is settable,
Stability
Superior to 0.1%FS/Year
Environmental Temperature
(-30~70)℃
Relative Humidity
<90%
Atmospheric Pressure
(86~106)kPa
Others
Correction reference environment temperature: :20℃±2℃
When 0.05%F.S , the gauge environment temperature :(0~50)℃
The Medium temperature
Normal (-40~120)℃
Wide Temperature(-60~150)℃
Display
5 digits LCD + percentage bar chart
Protection Grade
IP65
Explosion Proof Grade
ExiaIICT4 Ga
Over Load Pressure
(1.5~3) times of the measure range, depends on the measure range
Software
AncnView-T analysis software ( with USB communication), can Export instrument data, automatic storage, automatic drawing temperature curve, can be exported to Excel form, read, print,